DESIGN RULES
THE LIMITS OUR CAM ENGINEERS APPLY
These are the design rules our CAM engineers apply to incoming Gerber files. They are published so you can check a layout before you send it. A design outside these limits is not rejected automatically, but it moves to engineering review and may change the quotation or the lead time.
BOARD TYPES WE BUILD
01
Drill diameter and aspect ratio
| Parameter | Limit |
|---|---|
| Aspect ratio (board thickness / drill diameter) | 12:1 recommended, 20:1 maximum, 10:1 preferred for heavy copper |
| Minimum hole diameter, 0.5-2 oz copper | 0.2 mm |
| Minimum hole diameter, 0.5/1 oz (extreme) | 0.125-0.15 mm |
| Minimum hole, 3-6 oz heavy copper, 4-8 layers | 0.25 mm |
| Minimum hole, 3-6 oz heavy copper, 10-16 layers | 0.4 mm |
| Minimum hole, 3-6 oz heavy copper, 18-26 layers | 0.5 mm |
02
Hole-to-copper clearance
| Layer count | Inner layer | Outer layer |
|---|---|---|
| 4 layers | at least 5 mil | at least 7 mil |
| 6 layers | at least 6.5 mil | at least 9 mil |
| 8 layers | at least 7 mil | at least 10 mil |
| 10-18 layers | at least 7.5 mil | at least 11 mil |
| more than 18 layers | at least 8 mil | at least 12 mil |
03
Non-plated holes and slots
| Parameter | Recommended | Minimum |
|---|---|---|
| Non-plated hole to copper | 8 mil | 7 mil |
| Plated slot to hole edge (PTH) | 0.5 mm | 0.3 mm |
| Non-plated slot to hole edge (NPTH) | 1.0 mm | 0.5 mm |
04
Trace width and clearance
- Line and space: 3/3 mil is the recommended baseline and rises to 9/13 mil as copper thickness increases.
- Trace to copper: 5.5 mil recommended, 4.5 mil minimum.
- Copper to board edge: 10 mil recommended.
05
Solder mask and legend
- Solder mask opening: non-solder-mask-defined (NSMD) by default; at least 1.5 mil opening, at least 4 mil mask bridge, at least 2 mil trace coverage at the opening edge.
- Minimum solder mask bridge on the finished board: 0.08 mm.
- Minimum legend height: 0.6 mm on prototypes, 0.7 mm in production. Minimum legend line width 0.1 mm.
06
Routing
- Router bit: 0.8 mm or larger as standard, 0.5 mm only by special arrangement.
- Slots must be at least 0.1 mm larger than the router bit used to cut them.
07
Where these limits come from
These figures come from our own process capability documents and are the same ones used in DFM review. If your design sits outside a limit, send it anyway: engineering review often finds a workable route, and you will get an answer before production starts rather than after.
NEXT STEP
NOT SURE YOUR DESIGN CLEARS THESE LIMITS?
Send the Gerbers. DFM review tells you where it stands before anything is fabricated.

English 